  Tier 1-Optical Loss Testing


  Tier 1 Certification-Optical Loss Testing


  In its simplest form and optical loss testing is a comparison between the optical power measured in dBm at the output of the light source and the power measured at the far end of a fiber connected to that same light source.The difference is known as loss or attenuation,expressed in dB.


  Combining the light source/power meter,measuring against standards and providing a pass/fail is known as an Optical Loss Test Set.

202311221511211631.jpg

  AEM OTDR光時(shí)域反射計(jì)


  Tier 2 Testing


  TIA-568:Optical Fiber Cabling and Components Standard


  Tier 2 testing supplements Tier 1 testing with the addition of an OTDR characterization of the elements along the fiber cabling.


  Simply put,Tier 2 is just testing the same fiber with an OLTS and an OTDR and documenting the results of both.

202311221511518801.jpg

  AEM OTDR光時(shí)域反射計(jì)


  AEM OTDR Specifications


  Available wavelengths


  MM 850nm/1300nm


  SM 1310nm/1550nm


  Event dead zone


  0.5m to 0.7 depending on wavelength


  Attenuation dead zone


  2.5m to 4.5m depending on wavelength


  Dynamic Range


  25dB 850nm/27dB 1300nm


  29dB 1310nm/27dB 1550nm

202311221511711121.jpg

  Distance Measurement Range


  9km for 850nm,35km for 1300nm


  80km for 1310nm,130km for 1550nm


  Pulse Width


  3,5,10,15,…,24995,25000 nsec


  Individual adapters AD-OTDR-SM/AD-OTDR-MM are boxed and include 1 each of:


  SC interface

202311221511810151.jpg

  2m SC-SC TRC(“connector protectors”)


  LC&SC coupler


  1.25mm&2.5mm connector cleaners


  AEM OTDR光時(shí)域反射計(jì)


  Standalone OTDR kits/combination kits K21E/K41E/K71E include a hard case.

202311221511811251.png

  Launch cords are included ONLY with the Tier 1/Tier 2 combination kit K41E and the Smart Building Max kit K71E and must be purchased separately for all other configurations.


  AEM OTDR光時(shí)域反射計(jì)


  AEM OTDR光時(shí)域反射計(jì)


  Tier 2 Testing


  TIA-568:Optical Fiber Cabling and Components Standard


  Tier 2 testing supplements Tier 1 testing with the addition of an OTDR characterization of the elements along the fiber cabling.


  Simply put,Tier 2 is just testing the same fiber with an OLTS and an OTDR and documenting the results of both.


  以下為英文介紹資料,請(qǐng)酌情參考。


  Tier 1-Optical Loss Testing


  Tier 1 Certification-Optical Loss Testing


  In its simplest form and optical loss testing is a comparison between the optical power measured in dBm at the output of the light source and the power measured at the far end of a fiber connected to that same light source.The difference is known as loss or attenuation,expressed in dB.


  Combining the light source/power meter,measuring against standards and providing a pass/fail is known as an Optical Loss Test Set.